高壓細水霧分區控制閥關(guān)鍵功能是接收消防報警系統控制板的操作數據信號,打開(kāi)相對系統分區的電動(dòng)截止閥,將細水霧釋放到保護區進(jìn)行滅火。那么高壓細水霧滅火系統應用分區控制閥的性能特點(diǎn)是什么呢?
The key function of the high-pressure water mist partition control valve is to receive the operation data signal from the control panel of the fire alarm system, open the electric stop valve relative to the system partition, and release the water mist to the protection area for fire extinguishing. So what are the performance characteristics of partition control valve in high-pressure water mist fire extinguishing system?
多種啟動(dòng)方式,電動(dòng)、機械應急啟動(dòng)。采用電動(dòng)球閥驅動(dòng)矩形,啟動(dòng)快。工作壓力范圍寬,可達16MPa。具有多種流量和壓力的高壓泵。高壓泵的主要部件由不銹鋼制成。按照系統真實(shí)情況,可以通過(guò)泵組合實(shí)現多種流量和壓力輸出。
Various startup modes, electric and mechanical emergency startup. The electric ball valve is used to drive the rectangle, which is fast to start. The working pressure range is wide, up to 16MPa. High pressure pump with multiple flows and pressures. The main components of the high-pressure pump are made of stainless steel. According to the real situation of the system, a variety of flow and pressure outputs can be realized through the combination of pumps.
根據不同的應用方法,開(kāi)式系統分區調壓閥有兩種應用方法:開(kāi)式系統軟件-由開(kāi)式系統分區調壓閥+開(kāi)式噴嘴組成。預作用系統軟件-由開(kāi)式系統分區調壓閥+閉式噴嘴組成。
According to different application methods, there are two application methods of open system partition pressure regulating valve: open system software - composed of open system partition pressure regulating valve + open nozzle. Pre action system software - consists of open system partition pressure regulating valve + closed nozzle.

高壓細水霧分區控制閥由電動(dòng)截止閥、手動(dòng)球閥、壓力控制器、氣壓計、外殼和連接管組成;其主要功能是接收火災報警控制器的控制信號,打開(kāi)相應分區的電動(dòng)截止閥,向保護區釋放細水霧。當噴嘴正常噴出細水霧時(shí),壓力開(kāi)關(guān)將反饋給火警控制器。
High pressure water mist zone control valve is composed of electric stop valve, manual ball valve, pressure controller, barometer, shell and connecting pipe; Its main function is to receive the control signal from the fire alarm controller, open the electric stop valve in the corresponding zone and release water mist to the protection area. When the nozzle sprays water mist normally, the pressure switch will feed back to the fire alarm controller.
分區控制閥配有緊固件螺母和焊管。用氬弧焊與焊管焊接后,用活接頭與閥組的進(jìn)出口連接。分區控制閥組安裝在保護區附近和保護區外,以方便發(fā)生火災時(shí)的緊急情況。分區控制閥組采用明裝和暗裝兩種方式安裝。
山東川消人員提醒大家在進(jìn)行暗裝時(shí),裝修前要檢查接縫是否密封好。
The zone control valve is equipped with fasteners, nuts and welded pipes. After welding with the welded pipe by argon arc welding, use the union to connect with the inlet and outlet of the valve group. The divisional control valve group is installed near and outside the protection area to facilitate the emergency in case of fire. The divisional control valve group is installed in two ways: open installation and concealed installation. Shandong Chuanxiao staff reminded everyone to check whether the joints are well sealed before decoration.
高壓細水霧滅火系統應用分區控制閥的性能特點(diǎn)內容便講解完畢了,如果您對消防設備感興趣或者有需求的話(huà)可以來(lái)川消網(wǎng)站
www.guizhouhuli.net咨詢(xún)了解,為您提供很好的相關(guān)設備。
The performance characteristics of zone control valve used in high-pressure water mist fire extinguishing system are explained. If you are interested in or need fire-fighting equipment, you can come to Chuanxiao website www.guizhouhuli.net Com to provide you with good relevant equipment.