  Fire hydrant is an important product in fire equipment, so the daily inspection of it can not be less, so that during the use of the “chain” will not appear, check to see how the water supply system. So what happens to the hydrant feed system?
  消防栓給水系統完成的主要功能是當火災時(shí),打開(kāi)消火栓箱,按下火警按鈕(火警按鈕可起到報警和啟動(dòng)消防泵的作用),一人接好水帶槍頭和水帶后奔向起火點(diǎn),另一人將水帶接到消火栓接口處,逆時(shí)針打開(kāi)閥門(mén),將水槍對準火源,直到撲滅火源為止。
  Fire hydrant water supply system's main function is when the fire germinal, open fire hydrant box, fire alarm button (fire alarm button can play the role of alarm and start the fire pump), one to connect the hose for spear head and ran to the fire hose, another person will be received hydrant hose joints, open the valve counterclockwise, aim the gun fire, until put out the fire.
  川消消火栓無(wú)水或壓力過(guò)小原因:管道中有漏水點(diǎn);管道開(kāi)關(guān)已經(jīng)關(guān)閉;穩壓泵不起作用。故障處理方法:檢查漏水點(diǎn),修復穩壓泵,確保消火栓管網(wǎng)有水且壓力要大于2.5公斤以上。
  Chuanxiao fire hydrant without water or pressure is too small reasons: there is water leakage in the pipeline; The pipe switch has been closed; The regulator pump is not working. Troubleshooting method: check the leakage point, repair the regulator pump, ensure that there is water in the hydrant pipe network and the pressure is greater than 2.5 kg.
  按下手動(dòng)按鈕能聯(lián)動(dòng)啟動(dòng)消防泵的原因:手動(dòng)按鈕接線(xiàn)松動(dòng);手報按鈕已損壞;聯(lián)動(dòng)控制柜故障;消防水泵啟動(dòng)柜故障或連接松動(dòng);消防水泵故障。故障處理方法:檢查各設備接線(xiàn)、設備本身器件,檢查泵本身電氣、機構部分有無(wú)故障并進(jìn)行排除。
  Press the manual button can linkage start the fire pump cause: the manual button wiring loose; The hand alarm button is damaged. Linkage control cabinet failure; Fire pump starting cabinet fault or loose connection; The fire pump is faulty. Troubleshooting method: check the wiring of the equipment, the device itself, check the pump itself electrical, mechanism part has no fault and remove.
  另外,室內消火栓安裝的時(shí)候需要多注意一些事項,比如不要隨意改變消火栓箱底預留孔位置,不能與周?chē)嚯x過(guò)小,造成消防水帶不能安裝消火栓上或使水帶形成彎折影響出水量。
  In addition, indoor fire hydrant installation needs to pay more attention to some matters, such as do not arbitrarily change the position of the fire hydrant box bottom reserved hole, can not be too small with the surrounding distance, resulting in the fire hose can not be installed on the fire hydrant or the water supply can be bent.
  川消消防栓給水系統會(huì )出現怎樣的故障?以上便是問(wèn)題的相關(guān)解答了,如果您想了解更多相關(guān)問(wèn)題就來(lái)川消網(wǎng)站www.guizhouhuli.net咨詢(xún)人員吧!
  Chuan Fire hydrant water supply system will appear what kind of failure? The above is the relevant answers to the problem, if you want to know more about the relevant problems to sichuan elimination website www.guizhouhuli.net consulting professionals!
上一篇:消防排煙系統故障維修需要注意什么?
下一篇:消防閥門(mén)發(fā)生內漏怎么處理?

相關(guān)產(chǎn)品 / Related products

RM新时代投资官网
RM新时代手机版 RM新时代赚钱项目 RM新时代新项目-百度知道 RM新时代官方网站|首入球时间 新时代app游戏 rm新世界 RM新时代有限公司 rm新时代足球交易平台 RM新时代新项目-百度知道 rm理财